Analytical Instrumentation MCQ Question Set 4
Choose a topic to test your knowledge and improve your Analytical instruments skills
1. Which of the following UV absorbance detectors provide a real time spectrum of the component of interest?
Continuous wavelength detector
Variable wavelength detector
Scanning wavelength detector
Fixed wavelength detector
2. Fluorescence detection is less selective than absorption detection.
True
False
all of the above
None of the mentioned
3. Which of the following detectors depend on Snell’s law at the interface between the cell wall and the flowing liquid to deflect the light beam?
Electrochemical detectors
Fluorescence detectors
Refractive index detectors
Thermal conductivity detectors
4. Refractive index detectors used in liquid chromatography are not based on which of the following processes?
Interference
Refraction
Reflection
Absorption
5. Which of the following detectors can be used for detection of amino acids in protein hydrolyzates by introducing the reagent dansylchloride in the sample?
Electrochemical detectors
Fluorescence detectors
Refractive index detectors
Thermal conductivity detectors
6. The reference cell is packed with which of the following in the Adsorption detector used in liquid chromatography?
Inactive glass beads
Porous glass beads
Alumina
Silica
7. Which of the following detectors used in liquid chromatography is also called micro-adsorption detector?
Electrochemical detectors
Fluorescence detectors
Refractive index detectors
Thermal detectors
8. In UV-Visible detectors, the cells are not made of which of the following materials?
Quartz
Teflon
Silica
KELF
9. Which of the following is not a feature of refractive index type detectors?
Higher potential sensitivity
Low cost
High volume flow rates
Easy cell accessibility
10. Which of the following detectors can detect almost any component?
Combining two UV detectors
Combining RI and UV detectors
Mass detector
Laser-based detectors
11. Chromatography is a physical method that is used to separate and analyse _______
Simple mixtures
Complex mixtures
Viscous mixtures
Metals
12. In chromatography, the stationary phase can be _____supported on a solid.
Solid or liquid
Liquid or gas
Solid only
Liquid only
13. Which among the following gases have diamagnetic property (ability to be repelled by magnetic fields)?
Oxygen
Nitrogen
Nitrogen dioxide
Nitric oxide
14. Which of the following gases have paramagnetic property (ability to get attracted to a magnetic field)?
Nitric oxide
Hydrogen
Helium
Nitrogen
15. The force produced during the operation of Paramagnetic oxygen analyzer is proportional to which of the following?
Magnetic susceptibility of sphere
Magnetic susceptibility of surrounding gas
Difference between magnetic susceptibility of sphere and magnetic field strength
Difference between magnetic susceptibility of sphere and that of surrounding gas
16. In Paramagnetic oxygen analyzer, the expression for magnitude of force produced can be expressed as, F = C (K-KO), where K= magnetic susceptibility of surrounding gas and KO= magnetic susceptibility of sphere. C denotes which of the following?
Magnetic field strength
Magnetic gradient
Function of magnetic field strength and gradient
Magnetic flux
17. In Paramagnetic oxygen analyzer, the electrostatic force that is exerted should have which of the following features?
It should be greater than the magnetic field and must be in the same direction
It should be equal to the magnetic field and must be in the same direction
It should be greater than the magnetic field and must be in the opposite direction
It should be equal to the magnetic field and must be in the opposite direction
18. Which of the following is true about the two charged vanes that produce electric field in Paramagnetic oxygen analyzer?
Both the vanes should be at higher potential than the test body
Both the vanes should have the same potential as the test body
One vane should be at higher potential than the test body and the other vane should be at lower potential
Both the vanes should be at lower potential than the test body
19. In Paramagnetic oxygen analyzer, when no oxygen is present the magnetic force balances torque of the fibre.
True
False
all of the above
None of the mentioned
20. To improve paramagnetic oxygen analyzer, the quartz suspension must be replaced with which of the following?
Platinum-iridium
Phosphor-bronze
Gold-palladium
Antimony
21. In the Beckman instrument, the flow rate recommended when the sample enters through a porous diffusion disc is which of the following?
100-200 cc/min
50-250 cc/min
40-60 cc/min
200-300 cc/min
22. In the Beckman instrument, the flow rate recommended when the sample enters directly for rapid response is which of the following?
100-200 cc/min
50-250 cc/min
40-60 cc/min
200-300 cc/min
23. Which of the following happens to the magnetic susceptibility of gases when the temperature changes?
It increases with increase in temperature
It decreases with increase in temperature
It remains constant with increase in temperature
It remains constant with decrease in temperature
24. If the oxygen content is not greater than 21%, which of the following gases must be used to set the span point?
Oxygen
Dry air
Nitrogen
Hydrogen
25. If the oxygen content is greater than 21%, which of the following gases must be used to set the span point?
Oxygen
Dry air
Nitrogen
Hydrogen
26. Which of the following does not occur in Hartman and Braun oxygen analyzer based on the magnetic wind?
Oxygen is attracted to the magnetic field
Oxygen becomes less paramagnetic due to rise in temperature
Resistance change in a resistance connected to the Wheatstone bridge occur
Wheatstone Bridge becomes balanced due to temperature change
27. Which of the following is not a cause of the error that could occur in Hartman and Braun oxygen analyzer based on the magnetic wind?
The filament temperature could be affected by changes in thermal conductivity of the carrier gas
Hydrocarbons in sample stream may react on the heated filaments
Gravitation chimney flow effect lead to errors when cross tube is horizontal
Combustible gases may react on the heated filaments
28. Hydrocarbons need to be removed from the sample gas to avoid errors in Hartman and Braun oxygen analyzer.
True
False
all of the above
None of the mentioned
29. Magnetic wind analyzers are also known as which of the following?
Thermo-magnetic analyzers
Electro-magnetic analyzers
Thermo-analytical analyzers
Hot wire analyzers
30. In OXYMAT-M oxygen analyser which of the following is usually used as reference gas?
Hydrogen
Nitrogen
Helium
Ambient air
31. Which of the following is used in magnetic wind instruments to determine the amount of oxygen?
Change in resistance
Change in capacitance
Change in inductance
Change in concentration
32. Which of the following concepts are not used in magnetic wind instruments?
Change in resistance due to cooling by magnetic wind
Displacement of membrane by magnetised oxygen
Difference in pressure difference between two gases having varying concentration of oxygen
By measuring temperature using thermometer
33. How are the hydrocarbons in the samples removed in magnetic wind instruments?
By using a cold trap
By using a filter
By using a semipermeable membrane
By using magnetic effect
34. Which of the following bridges are used in magnetic wind instruments?
Wheatstone bridge
Kelvin’s bridge
Anderson’s bridge
Schering’s bridge
35. The extremely high inertia of the thin membrane in the oxygen sensor allows it to rapidly attain equilibrium.
True
False
all of the above
None of the mentioned
36. Nitrogen dioxide can be detected with a paramagnetic analyser.
True
False
all of the above
None of the mentioned
37. Nitrogen oxide cannot be directly analysed using UV and Visible analyzers due to which of the following reasons?
Less accuracy
Very low range
It leads to contamination of the sample
It is transparent in UV visible regions
38. How is NO converted to NO2 for analysis in UV and Visible analyzers?
Treating sample gas with pressurized oxygen
Treating sample gas with ozone
Treating sample gas with oxygen at low pressure
Treating sample gas with water at high pressure
39. How is NO converted to NO2 for analysis in Chemiluminescent analyser?
Treating sample gas with pressurized oxygen
Treating sample gas with ozone
Treating sample gas with oxygen at low pressure
Treating sample gas with water at high pressure
40. During analysis of NO2 using Chemiluminescent analyser, why is NO2 not made to react with ozone directly?
Less accuracy
It is a slow process
It leads to contamination of the sample
It does not produce luminescence
41. The instruments based on chemiluminescence maintain linearity in which of the following ranges?
1ppb to 100ppb
100ppb to 1000ppb
1ppb to 1000ppb
100ppb to 1000ppb
42. How can absorption be enhanced while determining NO concentration using CO laser?
By converting NO into NO2
By placing NO in a magnetic field
By using proper monochromators
By using choppers
43. Which of the following detectors are generally used for detection in NO analysis using CO laser?
Photomultiplier tube
Photovoltaic cell
Liquid nitrogen cooled Ge-Au element
Photo emissive tube
44. Which of the following analyzers are used to measure trace amounts of nitrogen oxides in the stratosphere?
Chemiluminescence
CO laser method
Laser opto-acoustic spectroscopy
Colorimetry
45. A pink coloured dye complex is formed when air containing NO2 is passed in an absorbing solution consisting of __________ and diamine dissolved in the acetic acid medium.
Sulphuric acid
Sulphonyl
Sulphonic acid
Sulphanilic acid
46. In Laser Opto-acoustic spectroscopy, the IR beam excites the molecules to higher states. In which of the following ways do the molecules return to the ground state?
Collisional de-excitation
Random de-excitation
By spontaneous emission
By stimulated emission
47. To monitor oxides of nitrogen in stack effluents, the sample containing oxides of nitrogen is passed through a flask containing solution of H2O2 in sulphuric acid. Nitric acid is formed. The nitrate ions then react with phenol-disulphonic acid to produce blue colour.
True
False
all of the above
None of the mentioned
48. Which of the following is not an advantage of electrochemical cells used for analysis of H2S?
Portable battery operated instrument
Pocket sized instrument
No pumps are needed
No interference from background gases
49. Which of the following methods are mainly used in combustible gas detection equipment?
Lead acetate tape staining method
Solid state sensor
Gold film sensor
Electrochemical cells
50. Which of the following is not an advantage of solid state sensor used for analysis of H2S?
No sampling system
It can be used in conditions involving vibration
It can be used in corrosive atmosphere
No interference from background gases