Biomedical/Biomedical%20Instrumentation%20MCQs%20%C3%A2%E2%82%AC%E2%80%9C%20Ambulatory%20Monitoring%20Instruments Sample Test,Sample questions

Question:
 Full form of P-FCB is ________

1.Planar-Functional Circuit Board

2.Planar-Fashionable Circuit Branch

3.Planar-Functional Circuit Board

4.Planar-Fashionable Circuit Board

Posted Date:-2022-04-28 16:49:33


Question:
 In the data recording, the normal speed of sub miniature tape recorder is ___________

1.3 cm/s

2. 2 cm/s

3.3 mm/s

4.2 mm/s

Posted Date:-2022-04-28 16:31:26


Question:
 What is the used in Tocodynamometry to sense changes in uterine tension transmitted to abdominal skin surface?

1.U-Manometer

2.Barometer

3.Tocotonometer

4.Picometer

Posted Date:-2022-04-28 16:21:35


Question:
A cardioscope differ in one important aspects as compared to the conventional instrument.

1.True

2.False

Posted Date:-2022-04-28 16:54:55


Question:
AECG technique fails in those rare cases where the amniotic fluid fails to provide adequate electrical coupling from foetus to mother.

1.True

2.False

Posted Date:-2022-04-28 08:14:57


Question:
Ambulatory monitoring of ECG is called ____________

1.Event Cardiography

2.Holter Cardiography

3.Real-Time Cardiography

4.Implantable Cardiography

Posted Date:-2022-04-28 16:26:22


Question:
An alarm system is used to produce signal in event of abnormalities occurring in heart rate.

1.True

2.False

Posted Date:-2022-04-28 16:58:37


Question:
Cardiotocographs are designed to measure and record foetal heart rate on an average basis.

1.True

2.False

Posted Date:-2022-04-28 16:22:42


Question:
Disposable type pregelled electrodes to pick up ____________ signal in cardiac monitor.

1.EOG

2.EMG

3.ECG

4.PCG

Posted Date:-2022-04-28 16:53:10


Question:
FHR yields important information about the status of ________

1.fats

2.eye

3.fibrous joint

4.foetus

Posted Date:-2022-04-28 16:16:54


Question:
Foetal ECG signal detected via electrodes placed on mother’s abdomen is complex and requires accertion of maternal signals for obtaining FHR.

1.True

2.False

Posted Date:-2022-04-28 08:14:33


Question:
Foetal Heart sounds are listened by digital stethoscope.

1.True

2.False

Posted Date:-2022-04-28 16:17:17


Question:
For rehabilitation engineering perspective a task that is specific to a single sense or movement pattern is called ___________

1.Functional Limitation

2.Societal Limitation

3.Modality-Specific

4.Pathophysiology

Posted Date:-2022-04-28 17:01:41


Question:
How is the assessment of the condition of foetus can be made during labour?

1.activity of sweat glands

2.baseline value of skin resistance

3.by foetal heart action

4.baseline value of breathing

Posted Date:-2022-04-28 16:18:51


Question:
How many heart beat one can observe in a single sweep period?

1.1

2.2

3.3

4.4

Posted Date:-2022-04-28 16:56:50


Question:
In data recorders, during replay, the tape is run at ________ to achieve rapid manual or automatic scanning of ambulatory records.

1.80 times of recording speed

2.70 times of recording speed

3.60 times of recording speed

4.50 times of recording speed

Posted Date:-2022-04-28 16:32:14


Question:
Interruption or interference with normal physiological and developmental processes or structures is called _________

1.Functional Limitation

2.Pathophysiology

3.Societal Limitation

4.Modality-Specific

Posted Date:-2022-04-28 17:01:03


Question:
Sensitivity of _______ bpm/cm of the recording chart allows adequate reading of the recorded FHR.

1.5

2.10

3.15

4.20

Posted Date:-2022-04-28 16:20:54


Question:
The current state of Holter technology uses small recorders, which size is about _______

1.75 x 20 x 90 cm

2.75 x 95 x 20 cm

3.75 x 20 x 95 mm

4.75 x 95 x 20 mm

Posted Date:-2022-04-28 16:28:10


Question:
The F channel has a _______ ms pulse generator that is triggered by the foetal ECG.

1.5

2.10

3.20

4.30

Posted Date:-2022-04-28 08:14:07


Question:
The foetus heart rate is approximately _______ time/s of normal adult foetal heart rate.

1.one

2.two

3.three

4.four

Posted Date:-2022-04-28 07:59:44


Question:
The monitor automatically transmits recorded data transtelephonically to a central monitoring station for subsequent analysis when an arrhythmia is detected by an arrhythmia algorithm.

1.True

2.False

Posted Date:-2022-04-28 16:30:47


Question:
The slow sweep is an outcome of the low frequency character of ________________ signal.

1.EMG

2.EOG

3.ECG

4.PCG

Posted Date:-2022-04-28 16:55:35


Question:
To listen to the foetal heart sounds at intervals of up to every _______ minutes is tradition.

1.5

2.10

3.15

4.20

Posted Date:-2022-04-28 16:18:05


Question:
What indicate average heart rate with audible beep?

1.disposable electrodes

2.heart rate meter

3.amplifier

4.cathode ray tube

Posted Date:-2022-04-28 16:57:32


Question:
What is delay time to establish a missing foetal trigger pulse by substitution logic?

1.150 ms

2.200 ms

3.250 ms

4.270 ms

Posted Date:-2022-04-28 08:16:20


Question:
What is diameter of CRT used in small cardioscopes?

1.1”

2.3”

3.5”

4.7”

Posted Date:-2022-04-28 16:58:07


Question:
What is present in the processing circuit for signal separation?

1.Preamplifier

2.Power Line Hum

3.Notch Filter

4.Band Pass Filter

Posted Date:-2022-04-28 08:12:52


Question:
What is range of RF signals generated by Electrosurgery machine?

1.0 to 0.4 MHz

2.0.4 to 5 MHz

3. 5 to 6.5 MHz

4.6.5 to 10 MHz

Posted Date:-2022-04-28 16:59:27


Question:
What is responsible for most of the common-mode interfering signal?

1.Preamplifier

2.Notch Filter

3.Power Line Hum

4.Band Pass Filter

Posted Date:-2022-04-28 08:11:12


Question:
What is the accuracy of measurement for the classification of responses?

1.1-2%

2.2-3%

3. 3-4%

4.4-5%

Posted Date:-2022-04-28 16:23:30


Question:
What is the CMRR of Foetal electrocardiogram?

1.0-150 dB

2.0- 130 dB

3.0-120 dB

4.0-200 dB

Posted Date:-2022-04-28 08:07:26


Question:
What is the magnitude of ECG for a typical adult in the standard lead connection?

1.1 mV

2.2 mV

3.3 mV

4.4 mV

Posted Date:-2022-04-28 08:02:15


Question:
What is the maximum amplitude of FECG recorded during pregnancy?

1.100 to 300 mV

2.300 to 500 mV

3.500 to 700 mV

4.700 to 900 mV

Posted Date:-2022-04-28 07:58:56


Question:
What is the range of FHR measurement due to substitution logic?

1.0-200 bpm

2.40-240 bpm

3.20-220 bpm

4.60-260 bpm

Posted Date:-2022-04-28 08:17:03


Question:
What is total sweep time for a 13-cm screen?

1.0 to 0.5 s

2.0.5 to 2 s

3.2 to 2.5 s

4.2.5 to 5 s

Posted Date:-2022-04-28 16:56:09


Question:
What is used for amplification of signal in cardiac monitor?

1.Piezoelectric device

2.Transducer

3.Amplifier

4.Tape recorder

Posted Date:-2022-04-28 16:53:49


Question:
Which CPU has an overall system control responsibility?

1.Control

2.Acquisition

3.Control and timing

4.Acquisition and display

Posted Date:-2022-04-28 16:48:25


Question:
Which is the most important physiological parameter monitored in the intensive care unit?

1.temperature

2.heart rate

3.blood pressure

4.skin color

Posted Date:-2022-04-28 16:50:32


Question:
Which of the following instrument carries out a continuous and simultaneous recording of the instantaneous foetal heart rate and labour activity?

1.Electrocardiograph

2.Cardiotocograph

3.Electromyograph

4.Vectorcardiograph

Posted Date:-2022-04-28 16:19:56


Question:
Which of the following instrument is also known as Cardioscopes?

1.Central Monitor

2.Bedside Patient Monitor

3.Cardiac Monitor

4.Blood Pressure Monitor

Posted Date:-2022-04-28 16:52:29


Question:
Which of the following instrument is used for monitoring patients with cardiac problems?

1.Cardiac Monitor

2.Central Monitor

3.Bedside Patient Monitor

4.Blood Pressure Monitor

Posted Date:-2022-04-28 16:51:41


Question:
Which of the following is a direct method for measuring foetal heart rate?

1.Abdominal foetal electrocardiogram

2.Foetal phonocardiogram

3.Ultrasound technique

4.Foetal ECG with scalp electrode

Posted Date:-2022-04-28 16:22:17


Question:
Which of the following is not an arrhythmic condition?

1.Cardiographic beat

2.Bradycardia

3.Dropped beat

4.Ectopic beat

Posted Date:-2022-04-28 16:33:15


Question:
Which of the following is periodic noise source in the foetal ECG signal from the maternal abdomen?

1.Amplifier input noise

2.Maternal Muscle noise

3.Fluctuations in electrode polarization potential

4.Maternal ECG

Posted Date:-2022-04-28 08:01:23


Question:
Which of the following storage device is used for storing digital information in memory monitors?

1.Hard disk

2.Magnetic Tape

3.RAM

4.DVD

Posted Date:-2022-04-28 17:00:13


Question:
Which of the following technique is used to measure foetal heart rate?

1.ECG

2.FECG

3.PCG

4.VCG

Posted Date:-2022-04-28 08:03:04


Question:
Which of the following type of systems are not available for ambulatory ECG monitoring?

1.Holter monitors

2.Event Recorders

3.Time Recorders

4.Implantable Loop Recorders

Posted Date:-2022-04-28 16:27:03


Question:
Who provides an excellent review of ambulatory cardiac event recorders?

1.Handelsman

2.Benz

3.Alfonso

4.Friesen

Posted Date:-2022-04-28 16:30:01


Question:
_____________ is used to display ECG which enable direct observation of the ECG waveform.

1.Amplifier

2.Transducer

3.Tape Recorder

4.Cathode ray tube

Posted Date:-2022-04-28 16:54:28


More MCQS

  1. Biomedical Instrumentation MCQs
  2. Biomedical Instrumentation MCQs Set 2
  3. Biomedical Instrumentation MCQs - Medical Diagnosis with Chemical Tests
  4. Biomedical Instrumentation MCQs Oximeters
  5. Biomedical Instrumentation MCQs Ambulatory Monitoring Instruments
  6. Biomedical Instrumentation MCQs Cardiac Monitor
Search
R4R Team
R4Rin Top Tutorials are Core Java,Hibernate ,Spring,Sturts.The content on R4R.in website is done by expert team not only with the help of books but along with the strong professional knowledge in all context like coding,designing, marketing,etc!