Biomedical/Biomedical Instrumentation MCQs Oximeters Sample Test,Sample questions

Question:
 In two-channel chart recorder, FHR is recorded on a calibrated chart in ________

1.cm/min

2.m/min

3.beats/min

4. pulses/min

Posted Date:-2022-04-27 09:24:23


Question:
 The transmitting crystal emits 40° divergent beam so that the beam covers an area of approximately _____ cm diameter.

1.10

2.20

3.30

4.40

Posted Date:-2022-04-27 08:47:54


Question:
A = ɛDC, where ɛ is _______

1.Incident light Intensity

2.Transmitted light Intensity

3. Extinction coefficient

4.Concentration

Posted Date:-2022-04-27 09:04:04


Question:
A = log I0/I,where I0 is_____

1.Incident light Intensity

2.Transmitted light Intensity

3.Extinction coefficient

4.Concentration

Posted Date:-2022-04-27 09:02:17


Question:
A pulse oximeter is useful in any setting where a patients oxygenation is unstable.

1.True

2.False

Posted Date:-2022-04-27 09:07:53


Question:
A pulse oximeter shows the percentage of venous hemoglobin in the oxyhemoglobin (HbO2) and hemoglobin (Hb).

1.True

2.False

Posted Date:-2022-04-27 09:04:29


Question:
A _______ channel chart recorder is incorporated in instruments used for monitoring labour activity.

1.one

2.two

3.three

4.four

Posted Date:-2022-04-27 09:22:09


Question:
At what angle divergent beam is transmitted by a crystal in array transducer?

1.10°

2.20°

3.30°

4.40°

Posted Date:-2022-04-27 08:43:04


Question:
In external toco-tonometry, movement of _____ may be superimposed on labour activity.

1.heart

2. eye

3.foetus

4.muscle

Posted Date:-2022-04-27 09:20:19


Question:
In phasing, if the cholesterol stream arrives at Y time, albumin must arrive at ______

1.Y + 5 s

2.Y + 10 s

3.Y + 15 s

4.Y + 20 s

Posted Date:-2022-04-27 08:58:17


Question:
In the sampling unit, when it is in its earlier form consisted of a circular turntable carrying around its rim 40 disposable __________ of 2 ml capacity.

1.Polyvinyl cups

2.Polythene cups

3.Polyester cups

4.Polystyrene cups

Posted Date:-2022-04-27 08:52:54


Question:
Portable pulse oximeters are useful for ______ whose oxygen levels may decrease at high altitude.

1.Athlete

2.Swimmer

3.Mountain climber

4.Fisher

Posted Date:-2022-04-27 09:08:33


Question:
The array transducer can be held in place by a simple buckle.

1.True

2.False

Posted Date:-2022-04-27 08:48:54


Question:
The array transducer housing is flexible to permit it to follow the contour of the abdomen regardless of shape changes with contractions.

1.True

2.False

Posted Date:-2022-04-27 08:42:22


Question:
The galvanometer, which needs a frequency response of only 3 MHz, is positioned by a servo motor through a silent step-down belt drive.

1.True

2.False

Posted Date:-2022-04-27 09:28:00


Question:
The instrument which carries out a continuous and simultaneous recording of the instantaneous foetal heart rate and labour activity is called _________

1.Ergometer

2.Cardiotocograph

3.Cardiotocometer

4.Cardiotonometer

Posted Date:-2022-04-27 09:26:01


Question:
The intrauterine pressure can reach values of 150 mmHg or more during the expulsion period.

1.True

2.False

Posted Date:-2022-04-27 09:28:21


Question:
The narrow beam transducer is very sensitive and produces a good trigger signal for instantaneous heart rate determination.

1.True

2.False

Posted Date:-2022-04-27 08:40:01


Question:
The narrow beam transducer permits the operator to position the baseline on the zero-level line of recording chart.

1.True

2.False

Posted Date:-2022-04-27 09:19:44


Question:
The toco-transducers are temperature sensitive.

1.True

2.False

Posted Date:-2022-04-27 09:17:04


Question:
There are two types of coils employed in the system, which are ____

1.Tygon coils and mixing coils

2.Mixing coils and tubing coils

3.Delay coils and tygon coils

4.Mixing coils and delay coils

Posted Date:-2022-04-27 08:56:13


Question:
Uterine contractions are calibrated in range of ______ in two-channel chart recorder.

1.0-100 mm Hg

2.100-200 mm Hg

3.200-300 mm Hg

4.300-400 mm Hg

Posted Date:-2022-04-27 09:25:02


Question:
What are labour-activity transducers?

1.temperature transducer

2.ultrasonic transducer

3.pressure transducer

4.piezoelectric transducer

Posted Date:-2022-04-27 09:18:36


Question:
What is intrauterine pressure during the expulsion period?

1.130 mm Hg

2.140 mm Hg

3.150 mm Hg

4.160 mm Hg

Posted Date:-2022-04-27 09:15:08


Question:
What is measured in the internal method using fluid-filled catheter?

1.IUP

2.ECG

3.IUC

4.EMG

Posted Date:-2022-04-27 09:20:56


Question:
What is the diameter of an array transducer?

1.2

2.4

3.6

4.8

Posted Date:-2022-04-27 08:48:31


Question:
What is the duration of uterine contractions in a normal patient in spontaneous active labour?

1.0 to 30 s

2. 30 to 70 s

3.80 to 100 s

4.110 to 150 s

Posted Date:-2022-04-27 09:16:31


Question:
What is the interval of uterine contractions in a normal patient in spontaneous active labour?

1.1 to 3 minutes

2.3 to 5 minutes

3. 5 to 7 minutes

4.7 to 9 minutes

Posted Date:-2022-04-27 09:15:51


Question:
What is the peak intensity of uterine contractions in a normal patient in spontaneous active labour?

1.0 to 35 mm Hg

2.50 to 75 mm Hg

3.90 to 120 mm Hg

4.120 to 150 mm Hg

Posted Date:-2022-04-27 09:17:43


Question:
What is the range of Instantaneous beat to beat rate digitally displayed?

1.0 to 50 bpm

2.50 to 210 bpm

3.210 to 350 bpm

4.350 to 410 bpm

Posted Date:-2022-04-27 09:21:35


Question:
What is the ratio of the sampling time to wash time?

1.1:2

2.3:1

3.2:1

4.1:3

Posted Date:-2022-04-27 08:53:35


Question:
What is the standard chart speed?

1.2 cm/min

2.3 cm/min

3.4 cm/min

4.5 cm/min

Posted Date:-2022-04-27 09:22:55


Question:
What is the wavelength of infrared LED in pulse oximetry?

1.660 nm

2.740 nm

3.905 nm

4. 950 nm

Posted Date:-2022-04-27 09:06:19


Question:
What is the wavelength of the red LED in pulse oximetry?

1.660 nm

2.740 nm

3.05 nm

4.950 nm

Posted Date:-2022-04-27 09:05:46


Question:
What is used as a photodetector in pulse oximetry?

1.Phototransistor

2.Solar cell

3.Photodiode

4.Photographic plates

Posted Date:-2022-04-27 09:05:01


Question:
What is used to convert the movement of transducer due to an increase of tension in uterus into an electric signal?

1.AC Amplifier

2.Strain guage

3.Synchronous detector

4.piezoelectric crystal

Posted Date:-2022-04-27 09:19:21


Question:
Where are the electrodes placed for recording foetal electrocardiogram?

1.heart

2.abdomen

3.brain

4.veins

Posted Date:-2022-04-27 09:31:32


Question:
Which coils are used to permit the channels to enter the calorimeter in the proper sequence?

1.Mixing coils

2.Delay coils

3.Solvaflex coils

4.Phasing coils

Posted Date:-2022-04-27 08:59:03


Question:
Which is the most important of all instrumental methods of analysis in clinical chemistry?

1.Colorimetry

2.Spectrophotometry

3.Pneumotachometry

4.Oximetry

Posted Date:-2022-04-27 09:29:41


Question:
Which method of the following is based on the absorption of electromagnetic radiation in visible, ultraviolet and infrared ranges?

1.Colorimetry

2.Spectrophotometry

3.Pneumotachometry

4.Oximetry

Posted Date:-2022-04-27 09:30:24


Question:
Which module consists of a pair of Perspex plates?

1.The dialyzer module

2.The recorder module

3.The sampling module

4.Heating bath module

Posted Date:-2022-04-27 08:52:04


Question:
Which of the following is not the part of the manifold?

1.Transmission tubing

2.Pump tubes

3.Platter

4. Plastic tubes

Posted Date:-2022-04-27 08:54:18


Question:
Which of the following is not the type of tubing?

1.Acidflex tubing

2.Glass tubing

3.Polypropylene tubing

4.Tygon

Posted Date:-2022-04-27 08:55:19


Question:
Which of the following transducer is used to detect foetal heart movements over a wider area?

1.piezo-electric

2.ultrasonic

3.array

4.pressure

Posted Date:-2022-04-27 08:40:38


Question:
Which transducer cannot be used in the same place as the foetal heart rate detector, thus the patient must have two transducers on her abdomen?

1.Cardiotocometer

2.Toco-tonometer

3.LVDT

4.IUPC

Posted Date:-2022-04-27 09:29:00


Question:
Which transducer is arranged in the shape of a clover leaf so that it provides a large area of illumination?

1.piezo-electric

2.ultrasonic

3.array

4.pressure

Posted Date:-2022-04-27 08:41:55


Question:
_____ is non-invasive method allowing the monitoring of the saturation of a patient’s hemoglobin.

1.Ear Oximetry

2.Pulse Oximetry

3.Skin-Reflectance Oximetry

4.Intravascular Oximetry

Posted Date:-2022-04-27 09:01:01


Question:
______ is very useful for patients having respiratory or cardiac problems because of their simplicity of use and the ability to provide continuous and immediate oxygen saturation levels.

1.Pulse Oximeter

2.Ear Oximeter

3.Skin Reflactance Oximeter

4.Intravascular Oximeter

Posted Date:-2022-04-27 09:11:55


Question:
_______ is a direct technique of uterine contraction in cardiotocographic monitoring.

1.Tocodynamometry

2.Intrauterine pressure measurement

3.Phonocardiometry

4.Ultrasound technique

Posted Date:-2022-04-27 09:27:34


Question:
________ is not an indirect method of foetal heart rate in cordiotocography monitoring.

1.Foetal ECG with scalp electrode

2.Foetal phonocardiogram

3.Abdominal foetal electrocardiogram

4.Ultrasound techniques

Posted Date:-2022-04-27 09:26:51


More MCQS

  1. Biomedical Instrumentation MCQs
  2. Biomedical Instrumentation MCQs Set 2
  3. Biomedical Instrumentation MCQs - Medical Diagnosis with Chemical Tests
  4. Biomedical Instrumentation MCQs Oximeters
  5. Biomedical Instrumentation MCQs Ambulatory Monitoring Instruments
  6. Biomedical Instrumentation MCQs Cardiac Monitor
Search
R4R Team
R4Rin Top Tutorials are Core Java,Hibernate ,Spring,Sturts.The content on R4R.in website is done by expert team not only with the help of books but along with the strong professional knowledge in all context like coding,designing, marketing,etc!