Analytical instruments/Analytical Instrumentation MCQ Question Set 13 Sample Test,Sample questions

Question:
 Auger electron spectroscopy involves the irradiation of the surface to be analysed with a beam of electrons of energy in the _________ range.

1.1-2 KeV

2. 2-4 KeV

3. 4-8 KeV

4.1-8 KeV

Posted Date:-2022-04-20 07:35:35


Question:
 Double-pass cylindrical mirror energy analyser has how many mirrors?

1. One

2. Two

3.Three

4.four

Posted Date:-2022-04-20 07:55:11


Question:
 Electron ionization can produce which of the following?

1.ESCA electron

2.Auger electron

3. Ion

4.Photon

Posted Date:-2022-04-20 07:33:10


Question:
 In Auger process, an electron drops to fill which of the following?

1.1s hole

2. 1p hole

3.2s hole

4.2p hole

Posted Date:-2022-04-20 07:35:01


Question:
532.5 eV matches which of the following specific atom type?

1.Carbon

2.Oxygen

3.Nitrogen

4.Argon

Posted Date:-2022-04-20 07:30:14


Question:
A basic X-ray source includes which of the following components?

1.Large target anode

2.Large target cathode

3.Small target anode

4.Small target cathode

Posted Date:-2022-04-20 07:38:01


Question:
AES is limited when it comes to very high resolution studies.

1. True

2.False

3.all of the above

4.None of the mentioned

Posted Date:-2022-04-20 07:32:25


Question:
AES is more sensitive than XPS because of which of the following factors?

1.Binding energies of electrons

2. Kinetic energies of electrons

3.Mass of electrons

4.Mass to charge ratio of electrons

Posted Date:-2022-04-20 07:37:25


Question:
Auger electron spectroscopy can be used for surface chemical analysis in a way similar to which of the following?

1.ESCA

2. SIMS

3. ISS

4.Ion spectroscopy

Posted Date:-2022-04-20 07:32:10


Question:
Both ISS and SIMS have depth profiling capability.

1.True

2.False

3.all of the above

4.None of the mentioned

Posted Date:-2022-04-20 08:01:45


Question:
By studying which of the following can we determine if the surface corresponds to C-O or C=O chemical form?

1.Mass of the electron

2.Energy of the carbon peak

3.Binding energy

4.Charge of electron

Posted Date:-2022-04-20 07:30:39


Question:
Charging effect can be suppressed by supplying flood of electrons having which of the following?

1. Uniform low energy

2.Uniform low mass

3.Uniform high energy

4.Uniform high mass

Posted Date:-2022-04-20 07:57:56


Question:
Electron detector has a _______ doped glass tube with a secondary semiconducting coating.

1.Quartz

2.Silica

3.Lead

4.Cesium

Posted Date:-2022-04-20 07:56:21


Question:
Electron ionisation can produce ESCA electrons.

1.True

2.False

3.all of the above

4.None of the mentioned

Posted Date:-2022-04-20 07:33:30


Question:
How is the specificity of Auger electron spectroscopy?

1.Very bad

2.Bad

3.Good

4.Very good

Posted Date:-2022-04-20 07:37:04


Question:
If the primary ion is elastically scattered, the kinetic energy of the reflected primary ion will depend on which of the following?

1.Charge of the primary ion

2. Charge of the surface ion

3.Mass of the surface ion

4.Number of surface ions

Posted Date:-2022-04-20 07:59:44


Question:
In Auger spectroscopy, beam currents are typically _____ in a beam of diameter 0.5mm.

1.5-10 µA

2.5-20 µA

3.5-30 µA

4.5-50 µA

Posted Date:-2022-04-20 07:35:57


Question:
In ESCA process, the photon ejects which of the following?

1.1s electron

2.1p electron

3.2s electron

4.2p electron

Posted Date:-2022-04-20 07:34:39


Question:
In ion spectroscopy, the positive ions are focussed on the sample at which of the following angles?

1.20o

2.30o

3.45o

4.90o

Posted Date:-2022-04-20 08:04:27


Question:
In Ion spectroscopy, the primary ion is usually which of the following?

1. Inert gas ion

2.Halogen ion

3.Oxygen group gas ion

4.Hydrogen

Posted Date:-2022-04-20 07:58:55


Question:
In order to obtain ISS spectra, the backscattered primary ions are sampled by which of the following?

1.Faraday cup analyser

2.Photographic analyser

3.Micro-channel analyser

4.Cylindrical mirror analyser

Posted Date:-2022-04-20 08:07:54


Question:
In spherical sector analyser, ____ is detected and plotted as a function of energy.

1. Mass

2.Charge

3.Number of electrons striking the detector

4.Mass to charge ratio of electrons

Posted Date:-2022-04-20 07:55:34


Question:
Magnetic deflection energy analysers are effective than electrostatic types.

1.True

2.False

3.all of the above

4.None of the mentioned

Posted Date:-2022-04-20 07:54:47


Question:
Only those electrons which are in a selected small solid angle are received in the ________ electrostatic analyser.

1.100o

2.127o

3.180o

4.263o

Posted Date:-2022-04-20 08:06:53


Question:
Qualitative chemical analysis is very often performed using which of the following?

1.ESCA

2.SIMS

3.AES

4. Ion spectroscopy

Posted Date:-2022-04-20 07:32:47


Question:
Synchroton radiation has several advantages over conventional radiation.

1.True

2.False

3.all of the above

4.None of the mentioned

Posted Date:-2022-04-20 07:58:14


Question:
The anode is held at __________ positive potential and the filament is held at ____________ potential.

1.High, ground

2.Ground, high

3. Low, high

4.High, low

Posted Date:-2022-04-20 07:38:30


Question:
The characterisation of auger spectroscopy can be achieved up to which of the following depths?

1.1 nm

2.2 nm

3.4 nm

4.8 nm

Posted Date:-2022-04-20 07:31:37


Question:
The fragments formed during sputtering can be either neutral atoms or ions. The ions can only be positive.

1.True

2.False

3.all of the above

4.None of the mentioned

Posted Date:-2022-04-20 08:00:34


Question:
The kinetic energy of the primary ion should be in which of the following range?

1.0.1-4 keV

2.0.2-1 keV

3.0.4-2 keV

4.0.3-5 keV

Posted Date:-2022-04-20 07:59:18


Question:
The output of the multiplier is fed to which of the following immediately?

1.Pulse amplifier discriminator

2.DAC

3.ADC

4.Multichannel analyser

Posted Date:-2022-04-20 07:56:44


Question:
Which is the most intense line in the X-ray spectrum?

1.Kα1

2. Kα2

3. Kα12

4.Kα22

Posted Date:-2022-04-20 07:39:18


Question:
Which of the following can be used as the detector in ion spectroscopy?

1. Faraday cup collector

2.Channel electron multiplier

3.Micro-channel plate

4.Flame ionization detector

Posted Date:-2022-04-20 08:07:19


Question:
Which of the following causes the phenomena of sputtering?

1.Primary ion gets embedded in the solid

2.Primary ion is elastically scattered

3. Primary ion is reflected

4.Primary ion is refracted

Posted Date:-2022-04-20 08:00:11


Question:
Which of the following denotes the sample destruction that occurs in Auger electron spectroscopy?

1.None in 95% of sample

2.None in 99% of sample

3.None in 100% of sample

4.Frequent

Posted Date:-2022-04-20 07:36:42


Question:
Which of the following is an Auger transition starting from a hole in 1s levels which would be filled up from the 2p level?

1.KLM transition

2.KLL transition

3.LMN transition

4.LLM transition

Posted Date:-2022-04-20 07:34:14


Question:
Which of the following is denotes the absolute quantitative analysis of SIMS?

1.30%

2.70%

3.50%

4.Not possible

Posted Date:-2022-04-20 08:02:10


Question:
Which of the following is one of the most commonly used anode material?

1. Carbon

2.Tungsten

3. Magnesium

4.Cesium

Posted Date:-2022-04-20 07:38:54


Question:
Which of the following is the amount of matrix effect that occurs in SIMS?

1.Very low

2.Low

3. Some

4.Severe

Posted Date:-2022-04-20 08:02:30


Question:
Which of the following is the detection limit of Auger Electron Spectroscopy?

1.0.1% monolayer

2.0.5% monolayer

3.1% monolayer

4.2% monolayer

Posted Date:-2022-04-20 07:36:20


Question:
Which of the following is the detection limit of ESCA?

1. 0.1% monolayer

2. 0.5% monolayer

3.1% monolayer

4.2% monolayer

Posted Date:-2022-04-20 07:31:01


Question:
Which of the following is the energy after collision with a surface atom for a scattering angle of 90o when Eo is the energy of the incident ion, M1 is the mass of the incident ion and M2 is the mass of the target surface?

1.Eo(M2-M1)/(M2+M1)

2.Eo(M2+M1)/(M2-M1)

3.Eo(M2×M1)/(M2+M1)

4.Eo(M2-M1)/(M2×M1)

Posted Date:-2022-04-20 08:08:27


Question:
Which of the following is the energy range of ISS?

1.1 keV

2. 2 keV

3.4 keV

4.8 keV

Posted Date:-2022-04-20 08:01:04


Question:
Which of the following is the ideal vacuum for electron spectrometers?

1.10-6 torr

2.10-7 torr

3.10-8 torr

4.10-9 torr

Posted Date:-2022-04-20 07:57:05


Question:
Which of the following is the most commonly used detector in ESCA and AES?

1.Electron multiplier

2.Dynodes

3.Photovoltaic cell

4.Photomultiplier

Posted Date:-2022-04-20 07:55:58


Question:
Which of the following is the most commonly used magnetic shielding?

1.Helmholtz coils

2.Ferro-magnetic shielding

3. Faraday shield

4.Magnetometer probe

Posted Date:-2022-04-20 07:57:30


Question:
Which of the following is the spectral range of SIMS?

1. 0-10 amu

2.0-100 amu

3.0-500 amu

4. 0-1000 amu

Posted Date:-2022-04-20 08:01:27


Question:
Which of the following is the x-y resolution of ISS?

1.1 µ

2.10 µ

3.100 µ

4. 1000 µ

Posted Date:-2022-04-20 08:02:58


Question:
Which of the following is the x-y resolution of SIMS?

1. 1 µ

2.10 µ

3. 100 µ

4.1000 µ

Posted Date:-2022-04-20 08:03:19


Question:
Which of the following must be used with the X-ray source to have high energy resolution?

1.Chopper

2.Vacuum chamber

3.Accelerator

4.Monochromator

Posted Date:-2022-04-20 07:40:03


More MCQS

  1. Analytical Instrumentation MCQ Question Set 1
  2. Analytical Instrumentation MCQ Question Set 2
  3. Analytical Instrumentation MCQ Question Set 3
  4. Analytical Instrumentation MCQ Question Set 4
  5. Analytical Instrumentation MCQ Question Set 5
  6. Analytical Instrumentation MCQ Question Set 6
  7. Analytical Instrumentation MCQ Question Set 7
  8. Analytical Instrumentation MCQ Question Set 8
  9. Analytical Instrumentation MCQ Question Set 9
  10. Analytical Instrumentation MCQ Question Set 10
  11. Analytical Instrumentation MCQ Question Set 11
  12. Analytical Instrumentation MCQ Question Set 12
  13. Analytical Instrumentation MCQ Question Set 13
  14. Analytical Instrumentation MCQ Question Set 14
  15. Analytical Instrumentation Colorimetry and Spectrometry MCQ
  16. Analytical Instrumentation MCQ Question Set 15
  17. Analytical Instrumentation MCQ Question Set 16
  18. Analytical Instrumentation MCQ Question Set 17
  19. Analytical Instrumentation MCQ Question Set 18
  20. Analytical Instrumentation MCQ Question Set 19
  21. Analytical Instrumentation MCQ Question Set 20
  22. Analytical Instrumentation MCQ Question Set 21
  23. Analytical Instrumentation MCQ Question Set 22
  24. Analytical Instrumentation MCQ Question Set 23
  25. Analytical Instrumentation MCQ Question Set 24
  26. Analytical Instrumentation MCQ Question Set 25
  27. Analytical Instrumentation MCQ Question Set 26
  28. Analytical Instrumentation MCQ Question Set 27
  29. Analytical Instrumentation MCQ Question Set 28
  30. Analytical Instrumentation MCQ Question Set 29
  31. Analytical Instrumentation MCQ Question Set 30
  32. Analytical Instrumentation MCQ Question Set 31
  33. Analytical Instrumentation MCQ Question Set 32
  34. Analytical Instrumentation MCQ Question Set 33
  35. Analytical Instrumentation MCQ Question Set 34
Search
R4R Team
R4Rin Top Tutorials are Core Java,Hibernate ,Spring,Sturts.The content on R4R.in website is done by expert team not only with the help of books but along with the strong professional knowledge in all context like coding,designing, marketing,etc!