Analytical instruments/ Sample Test,Sample questions

Question:
 Bolometer, a type of detector, is also known as _____

1.Resistance temperature detector (RTD)

2.Thermistor

3.Thermocouple

4.Golay cell

Posted Date:-2022-04-02 08:25:04


Question:
 In the most widely used beam splitter, a thin film of ________ is sandwiched between two plates of low refractive index solid. Fill the blank with a suitable option.

1. Mylar

2.Silicon carbide

3.Ferrous oxide

4.Silver chloride

Posted Date:-2022-04-02 08:28:41


Question:
 Transmittance is given as T = P/Po. If Po is the power incident on the sample, what does P represent?

1.Radiant power transmitted by the sample

2.Radiant power absorbed by the sample

3.Sum of powers absorbed and scattered

4.Sum of powers transmitted and reflected

Posted Date:-2022-04-02 08:05:36


Question:
 Which of the following is not a technique for preparing solid samples in IR spectroscopy?

1. Solids run in solution

2.Mull technique

3.Solid films

4.Thin films

Posted Date:-2022-04-02 08:25:30


Question:
 Which of the following is the wave number of near infrared spectrometer?

1.4000 – 200 cm-1

2.200 – 10 cm-1

3.12500 – 4000 cm-1

4.50 – 1000 cm-1

Posted Date:-2022-04-02 08:23:18


Question:
Beer Lambert’s law gives the relation between which of the following?

1. Reflected radiation and concentration

2.Scattered radiation and concentration

3.Energy absorption and concentration

4.Energy absorption and reflected radiation

Posted Date:-2022-04-02 07:59:40


Question:
Beer’s law states that the intensity of light decreases with respect to ______

1.Concentration

2.Distance

3.Composition

4.Volume

Posted Date:-2022-04-02 08:03:34


Question:
Colorimeters are used in applications where great accuracy is required.

1.True

2.FALSE

3.all of the above

4.None of the mentioned

Posted Date:-2022-04-02 08:19:42


Question:
Electromagnetic radiation can travel through a vacuum.

1.True

2. False

3.all of the above

4.None of the mentioned

Posted Date:-2022-04-02 07:54:45


Question:
Gelation is affected by temperature in the environment

1.It permits continuous selection of different wavelength

2.It allows a narrow band of wavelengths to pass

3.It has two semi-transparent layers of silver

4.Space layer is made of a substance having low refractive index

Posted Date:-2022-04-02 08:10:32


Question:
How can stability of radiation be achieved in incandescent or discharge source used in Absorption Spectroscopy?

1.Using filters

2.Using monochromators

3.Using slits

4. By controlling the source voltage

Posted Date:-2022-04-02 08:15:39


Question:
How is the wave number of electromagnetic radiation related to wavelength?

1.It is the reciprocal of wavelength

2. It is directly proportional to wavelength

3.It is not related to wavelength

4.It is equal to wavelength

Posted Date:-2022-04-02 07:57:21


Question:
How is Tungsten Halogen lamp differs from normal Tungsten filament lamp used in absorption spectroscopy?

1. It has a tungsten filament and is filled with inert gas

2. It has a tungsten filament and is filled with inert gas

3. Iodine is coated on tungsten filament

4.Iodine is added to inert gas

Posted Date:-2022-04-02 08:08:56


Question:
In a solid sample treatment technique, the finely ground solid sample is mixed with mineral oil to make a thick paste which is then spread between IR transmitting windows. What is the name of this solid sample treatment technique?

1.Pressed pellet

2. Mull technique

3.Solid films

4. Solids run in solution

Posted Date:-2022-04-02 08:27:33


Question:
In photometers, the readings of the specimen are initially obtained in the form of which of the following parameters?

1.Transmittance

2.Absorption

3. Wavelengths

4.Volume

Posted Date:-2022-04-02 08:19:15


Question:
In which of the following ways, absorption is related to transmittance?

1.Absorption is the logarithm of transmittance

2.Absorption is the reciprocal of transmittance

3.Absorption is the negative logarithm of transmittance

4.Absorption is a multiple of transmittance

Posted Date:-2022-04-02 08:00:15


Question:
Instead of glass filters, why gelatin filters could not be used for a long period while both are Absorption filters?

1.Gelatin tends to evaporate and hence they deteriorate

2.Gelatin is affected by humidity in the environment

3.They deteriorate due to absorption of heat leading to changes in gelatin

4.Gelation is affected by temperature in the environment

Posted Date:-2022-04-02 08:09:42


Question:
Lambert’s law states that the intensity of light decreases with respect to ______

1. Concentration

2. Distance

3. Composition

4. Volume

Posted Date:-2022-04-02 08:04:13


Question:
Only pyroelectric transducer or pyroelectric crystals are used as detectors in Fourier Transform Infrared Spectrophotometer (FTIR). What is the main reason for other types of thermal detectors are not being used in FTIR spectrophotometer?

1.Less accuracy

2.Slower response

3.Less precision

4.Less sensitivity

Posted Date:-2022-04-02 08:29:40


Question:
The representation of Beer Lambert’s law is given as A = abc. If ‘b’ represents distance, ‘c’ represents concentration and ‘A’ represents absorption, what does ‘a’ represent?

1.Intensity

2.Transmittance

3.Absorptivity

4. Admittance

Posted Date:-2022-04-02 08:04:38


Question:
To tolerate high operating temperatures, which of the following has to be done in incandescent or tungsten filament lamps?

1. Alloys must be used

2.Nitrogen be used instead of inert gas

3.Envelope is fabricated with quartz

4.Envelope is fabricated with copper

Posted Date:-2022-04-02 08:16:11


Question:
Velocity of electromagnetic radiation is more in a vacuum than in any medium.

1.True

2.False

3.all of the above

4.None of the mentioned

Posted Date:-2022-04-02 07:58:38


Question:
What is the composition of Globar rod which is used as a source in Mid IR spectroscopy?

1.Silicon carbide

2. Silver chloride

3.Silicon dioxide

4.Silver carbide

Posted Date:-2022-04-02 08:24:38


Question:
What is the unit of absorbance which can be derived from Beer Lambert’s law?

1.L mol-1 cm-1

2.L gm-1 cm-1

3.Cm

4.No unit

Posted Date:-2022-04-02 08:06:02


Question:
What is the unit of molar absorptivity or absorptivity which is used to determine absorbance A in Beer Lambert’s formula?

1. L mol-1 cm-1

2. L gm-1 cm-1

3. Cm

4.No unit

Posted Date:-2022-04-02 08:06:29


Question:
Which of the following could be used as the layer of dielectric in interference filters used in Absorption Spectroscopy?

1.Graphite

2.MgF2

3. Fe

4.AgNO3

Posted Date:-2022-04-02 08:11:00


Question:
Which of the following detectors does not require a battery and is also known as barrier layer cell?

1.Photomultiplier tube

2.Photovoltaic cell

3. Photoemissive tubes

4.Photo reflector

Posted Date:-2022-04-02 08:07:37


Question:
Which of the following detectors is used to detect light intensities which are very weak?

1. Photomultiplier tube

2. Photomultiplier tube

3.Photoemissive tubes

4.Photo reflector

Posted Date:-2022-04-02 08:08:09


Question:
Which of the following is a source used in spectroscopy?

1.LASER

2.Tube light

3.Sodium vapour lamp

4.Tungsten lamp

Posted Date:-2022-04-02 08:22:15


Question:
Which of the following is false about the wavelengths of electromagnetic radiation?

1.Radiation with short wavelengths have high energies

2.Energy does not depend on wavelength

3.Radiation with long wavelengths have low energies

4.Energy depends on wavelength

Posted Date:-2022-04-02 07:55:59


Question:
Which of the following is not a composition of Nernst glower or Nernst filament?

1. Oxides of Zirconium

2.Oxides of Barium

3.Oxides of Yitrium

4.Oxides of Thorium

Posted Date:-2022-04-02 08:24:09


Question:
Which of the following is not a limitation of Beer Lambert’s law, which gives the relation between absorption, thickness and concentration?

1. Concentration must be lower

2. Radiation must have higher bandwidth

3.Radiation source must be monochromatic

4.Does not consider factors other than thickness and concentration that affect absorbance

Posted Date:-2022-04-02 08:03:06


Question:
Which of the following is not a property or parameter of electromagnetic radiation?

1.Wavelength

2.Voltage

3.Wave number

4. Amplitude

Posted Date:-2022-04-02 07:53:32


Question:
Which of the following is not a reason for laser not being generally used as a source of radiation for UV, Visible Spectroscopy?

1.High cost

2.Limited range of wavelength

3.Less intensity

4. Complex to work with

Posted Date:-2022-04-02 08:16:39


Question:
Which of the following is not a source used in Mid Infrared Spectrophotometer?

1.Nernst glower

2.High pressure mercury arc lamp

3.Globar

4.Nichrome wire

Posted Date:-2022-04-02 08:22:52


Question:
Which of the following is not a type of Spectroscopy?

1.Gamma ray

2.X ray

3. Nuclear magnetic resonance

4.Sound

Posted Date:-2022-04-02 07:54:12


Question:
Which of the following is not an application of colorimeter?

1. Paints

2. Inks

3.Cosmetics

4.Composition detection

Posted Date:-2022-04-02 08:18:41


Question:
Which of the following is not the function of the drive mechanism in Fourier Transform Infrared Spectrophotometer?

1.Movement of mirror to obtain a satisfactory interferogram

2. Acquire a good interferogram pattern

3.Allow 50% of the beam to pass

4.Keep the speed of the moving mirror constant

Posted Date:-2022-04-02 08:29:12


Question:
Which of the following is not true about Absorption spectroscopy?

1. It involves transmission

2.Scattering is kept minimum

3. Reflection is kept maximum

4.Intensity of radiation leaving the substance is an indication of a concentration

Posted Date:-2022-04-02 08:05:09


Question:
Which of the following is not true about Fourier Transform Infrared (FTIR) spectrometer?

1.It is of non-dispersive type

2.It is useful where repetitive analysis is required

3.Size has been reduced over the years

4.Size has increased over the years

Posted Date:-2022-04-02 08:28:13


Question:
Which of the following is not used as pyroelectric material used in pyroelectric transducers in Infrared spectroscopy?

1.Triglycine Sulphate

2.Deutrated Triglycine Sulphate

3.Some Polymers

4.Tetraglycine sulphate

Posted Date:-2022-04-02 08:26:07


Question:
Which of the following is the principle of Golay cell which is used as a detector in IR spectroscopy?

1. Expansion of gas upon heating

2.Increase in resistance due to an increase in temperature and vice versa

3.Temperature difference gives rise to a potential difference in the material

4.Decrease in resistance due to an increase in temperature

Posted Date:-2022-04-02 08:27:06


Question:
Which of the following is the purpose of balance indicator in double beam photometer or colorimeter?

1.Selects a particular wavelength

2.Splits the wavelength selected into two equal beams

3.Detects and indicates the amount of light falling on it

4.Indicates the difference between the output of two photometers

Posted Date:-2022-04-02 08:20:22


Question:
Which of the following is the purpose of the beam splitter in double beam photometer or colorimeter?

1. Splits beam into two equal intensity beams

2. Splits beam into two equal intensity beams

3. Splits beam in such a way that a reference beam has higher intensity

4.Merge two equal intensity beams into single beam

Posted Date:-2022-04-02 08:21:53


Question:
Which of the following is the wavelength of microwave radiation?

1. 10 – 780nm

2.0.78 – 30µm

3.0.6 – 10 m

4.0.75 – 3.75 mm

Posted Date:-2022-04-02 07:56:39


Question:
Which of the following is the wavenumber of UV and Visible radiation?

1.1 x 106 to 1.3 x 104 m-1

2.1 x 106 to 1.3 x 104 m

3.13 – 27 m-1

4.1 x 106 to 1.3 x 104 m2

Posted Date:-2022-04-02 07:58:14


Question:
Which of the following options are correct in terms of wavelength for the different types of IR spectrometer?

1.Near IR: 0.8 – 2.5 mm

2.Mid IR: 0.8 – 2.5 mm

3.Far IR: 2.5 – 50 mm

4. Mid IR: 50 – 100 mm

Posted Date:-2022-04-02 08:23:42


Question:
Which of the following statement is false about double beam absorption instruments?

1. It is similar to single beam instruments except two beams are present

2. Tungsten bulb is used as a source

3.Reference beam must have a higher intensity than sample beam

4. Both the beams after they pass through respective samples are compared

Posted Date:-2022-04-02 08:18:17


Question:
Which of the following statements is false about single beam absorption instruments?

1.Tungsten bulb is used as a source

2.Beam splitter is used to get parallel beam

3.Test tube is used as sample holder

4.Photovoltaic cell as detector

Posted Date:-2022-04-02 08:17:32


Question:
Which type of Quantum Transition takes place in Ultra Violet and Visible spectroscopy?

1.Rotation of molecules

2.Nuclear

3.Bonding electrons

4.Spin of nuclei in a magnetic field